Keysight Three-Level Triggering 8 GHz 4 Analog Channels Dsos804A High-Definition Oscilloscope

Product Details
Customization: Available
Kind: Digital Oscilloscope
Channel Number: 4
Diamond Member Since 2025

Suppliers with verified business licenses

Year of Establishment
2025-04-01
Address
Room 801, 8th Floor, Building 2, No. 9 Qiande Road Jiangning District, Nanjing, Jiangsu, ...
  • Keysight Three-Level Triggering 8 GHz 4 Analog Channels Dsos804A High-Definition Oscilloscope
  • Keysight Three-Level Triggering 8 GHz 4 Analog Channels Dsos804A High-Definition Oscilloscope
  • Keysight Three-Level Triggering 8 GHz 4 Analog Channels Dsos804A High-Definition Oscilloscope
  • Keysight Three-Level Triggering 8 GHz 4 Analog Channels Dsos804A High-Definition Oscilloscope
  • Keysight Three-Level Triggering 8 GHz 4 Analog Channels Dsos804A High-Definition Oscilloscope
  • Keysight Three-Level Triggering 8 GHz 4 Analog Channels Dsos804A High-Definition Oscilloscope
Find Similar Products
  • Overview
  • Specification
  • After Sales Service
Overview

Basic Info.

Model NO.
DSOS804A High-Definition Oscilloscope
Structure
Desktop
Application
Voltage Measurement, Impedance Measurement, Phase Measurements, Time Measurement, Frequency Measurement
Sampling Mode
Real-time Sampling
Bandwidth
>1GHz
Trigger Modes
Three-Level Triggering
Deeper Memory Depth
400 Mpts
Sampling Rate
10 Gsa/S
Waveform Capture Rate
> 300,000 Wfm/S
Built-in Signal Source
With Built-in Signal Source
Vertical Resolution
10 Bits, up to 16 Bits with High-Resolution Mode
Enob (Typical)
6.4
DC Gain Accuracy
± 2% Full Scale (± 1% Typical)
Dynamic Range
+4 Divisions From Center Screen
Transport Package
Wooden
Specification
DSOS804A
Trademark
Keysight
Production Capacity
2000 Pieces/Year

Product Description

Introduction
The DSOS804A S-Series oscilloscopes have 8 GHz of bandwidth, a 15" XGA capacitive touch screen, and a 10-bit analog-to-digital converter.
Specification
8 GHz bandwidth
4 analog channels
Achieve up to 16 bits of vertical resolution with our advanced system architecture
Capture a longer signal trace with 20 GSa/s maximum sample rate and 100 Mpts/channel of standard memory
Get superior signal integrity with an average system effective number of bits (ENOB) of 8.1 bits at full bandwidth
Gain increased usability with the multi-touch supported 15-inch capacitive touch screen and solid state drive for fast boot and reliability
Improve your testing with a wide range of protocol, compliance, and analysis software
What's Included
Four N2873A 500-MHz passive probes
Probe accessory pouch
Keysight I/O libraries suite
Localized power cord, front panel cover
8 GHz BNC calibration cable
Keyboard and mouse
User guide and programmer's guide ship on oscilloscope drive
Keysight Three-Level Triggering 8 GHz 4 Analog Channels Dsos804A High-Definition Oscilloscope
Analog channel specifications

S.054A
S.104A
S.204A
S.254A
S.404A
S.604A
S.804A
Input Channels
DSO: 4 analog; MSO: 4 analog, 16digital
Bandwidth
(-3db)
50Ω
500MHz
1GHz
2GHz
2.5GHz
4GHz
6GHz5
8GHz5
1MΩ
500MHz
500MHz
500MHz
500MHz
500MHz
500MHz
500MHz
Vertical resolution
10 bits, up to16 bits with high-resolution mode
Typical rise/fall time







•10/90%
860ps
430ps
215ps
172ps
107.5ps
71.7ps
53.8ps
•20/80%
620ps
310ps
155ps
124ps
77.5ps
51.7ps
33.8ps
ENOB(typical, not using high-resolution mode)
8.1
7.8
7.5
7.4
7.2
6.8
6.4
Input impedance
50Ω ± 3.5%(typically+1%at25°C)

1MΩ ±1%(14 pF typical)
Input sensitivity
50Ω: 1 mV/div to1 V/div

1MΩ: 1 mV/div to 5 V/div
Input coupling
50Ω: DC

1MΩ: DC, AC(>11Hz)
Bandwidth limit filters
Analog: 20MHz, 200MHz

Digital: 18.3MHzup to scope bandwidth, in increments of100kHz(under1 GHz)  or 10MHz(1 GHz and above). Filter options: Brick Wall, 4th Order Bessel, or Bandpass
Channel-to-channel isolation
DC to 100MHz: 50 dB
100MHz to 1GHz: 40dB
>1GHz: 30 dB
DC gain accuracy
± 2% full scale(±1%typical)
Maxinput voltage
50Ω: ±5 V
1 MΩ: 30 VRMSor ± 40 VMAX(DC+VPEAK). Probing technology allows for testing of higher voltages; the included N2873A 10:1 probe supports 300 VRMS or± 400VMAX(DC+VPEAK).
No transient overvoltage allowed in either the 50 Ω or 1 MΩ path, with or without probes.
Offset range
50Ω
All verticalranges: ±12 divisions or ± 4 V, whichever is smaller
1MΩ
<10mV/div: ±2V
≥10mV/div: ±5V
≥ 20mV/div: ±10 V
≥100mV/div: ±20 V
≥1 V/div: ± 40 V
Offset accuracy
≤ 2 V: ±0.1div± 2mV±1%
≥ 2 V: ±0.1 div±2mV±1.5%
Dynamicrange
+4 divisions from center screen
DC voltage measurementaccuracy
Dual cursor: ±[(DC gain accuracy)+(resolution)]
Single cursor: ±[(DC gain accuracy) +(offsetaccuracy)+(resolution/2)]
Keysight Three-Level Triggering 8 GHz 4 Analog Channels Dsos804A High-Definition Oscilloscope
Keysight Three-Level Triggering 8 GHz 4 Analog Channels Dsos804A High-Definition Oscilloscope
Keysight Three-Level Triggering 8 GHz 4 Analog Channels Dsos804A High-Definition Oscilloscope
Keysight Three-Level Triggering 8 GHz 4 Analog Channels Dsos804A High-Definition Oscilloscope
After Sales Service
Standard Warranty: 12 months or 2,000 operating hours (whichever comes first).
Extended Warranty: Optional coverage up to 36 months.
Global Support: 24/7 technical assistance and spare parts supply.
Training: On-site or remote operation/maintenance training.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier